117 Plate Lifting Clamps 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Plate lifting clamps should be inspected before use to ensure that: • all markings are legible; • plate lifting clamps are free from nicks, gouges and cracks; • a clamp with the correct Working Load Limit has been selected with respect to the load to be lifted; • always make sure that the clamp is supporting the load correctly; • the WLL should be applied in a straight pull and overloads are not permitted; • clamps may not be heat treated as this may affect their Working Load Limit; • never repair or reshape a clamp by welding, heating or bending as this may affect the Working Load Limit. It is required that the products are regularly inspected and that the inspection should take place in accordance with the safety standards given in the country of use. This is required because the products in use may be affected by wear, misuse, overloading etc. with a consequence of deformation and alteration of the material structure. Inspection should take place at least every six months and even more frequently when the clamps are used in severe operating conditions. Instructions for use Plate lifting clamps type E and ES. Do not side load the lifting eye. E - ES Plate lifting clamps type EU and EUS. Load reduction should be applied as per load direction angle and corresponding remaining percentage of the Working Load Limit. EU - EUS Plate lifting clamps type EH and EHS. Full load may be applied up to a load direction angle of maximum 30˚. Do not use larger angles. EH - EHS 100% WLL